Online TVOC Gas Analyzer with Data Logger System

fixed-voc-gas-detector

TVOC Gas Detector Volatile Organic Compound)

TVOC Gas Detectors – We can provide a range of fixed sensors and portable gas monitors for the detection of Volatile Organic Compounds.

It is important for many industries to have accurate and fast detection of harmful TVOC gases to avoid the gas reaching dangerous toxic levels.

Discover our range of TVOC gas detector and associated instruments. Designed specifically for the detection of a wide range of volatile organic compounds. Our TVOC gas detector range includes:

Volatile Organic Compounds find wide use in industry.
  • Every process which involves the manipulation and the production of hydrocarbons emit’s VOC’s.
Technology Photoionisation Detectors (PID)
  • With a PID, the sample gas is exposed to deep ultraviolet light. The emitted light ionises targeted gases and they are then detected by the PID electronics and reported as a concentration (ppb or ppm).
  • PIDs can measure Volatile Organic Compounds (TVOCs) to very low concentrations. Considered the gold standard for VOC measurement, PIDs are compact and low power, with recently improved electronics and longer lamp life. An extended family of lamps now include better BTEX and chlorinated TVOC detection.  These sensors are pin-replaceable with the 4P90 pellistor.

Online Fixed Gas Detectors:

  • Fixed Gas Detectors developed on NDIR, Electrochemical, TVOC/PID, Catalytic Combustion, and Infrared Technologies. The GT series gas detectors are used to monitor flammable and toxic gases, oxygen, carbon dioxide,TVOC,HCL,NO2,H2S,SO2,CL2,NH3, and other inorganic gases.
For example industrial application:
  • oil refining
  • solvent release
  • Painting and industrial combustion
  • chemical processing
  • laboratories
  • petrochemical plant
  • Hazardous chemical storage
  • Process industry
Technical Specification
Value/Information

Sensor 

Photoionisation with 10.6 eV lamp

Detection ranges and sensitivity

20.0 ppm*    0.001 ppm
50.0 ppm*    0.01 ppm
1000 ppm*   0.1 ppm
4,000 ppm*      1 ppm

Detection time (T90)

<30 seconds (diffused)**

User interface

Display: OLED high contrast white on black: 128 (w) x 64 (h) pixels Screen size: 35 mm (w) x 17.5 mm (h)
3 magnetic switches with LED confirmation (up, down, MENU, ESC & enter). Magnetic actuator supplied.

Status indicator

Bright visible status indicator: YELLOW, BLUE, WHITE

Certification

II 2G Ex d ib IIC T4 Gb ATEX

Environmental specification

  • Diffused
    Op Temp: -40oC to +50oC
    Storage Temp: -40oC to +60oC
  • Pumped
    Op Temp: -20oC to +50oC
    Storage Temp: -20oC to +60oC
  • 0-100% RH and condensing humidity

Mechanical interface

2 x cable entry points with 3/4” NPT threads (left and right)
2 x 3/4” NPT to M20 Stainless steel (supplied)

Dimensions

Without pump: 200 (h) x 190 (w) x 125 (d) mm
With pump: 290 (h) x 190 (w) x 125 (d) mm

Mounting points

2 x M8

Input power

Working voltage: 24 Vdc Max. power: 7 watts

Outputs

4 to 20 mA (active and passive)
RS485 supports Modbus® protocol
Relay x 2 SPST (60 Vdc 2A) – configurable With Hooter Buzzer Alaram.